Publications by Date

2024 |2023 |2022 | 2021 | 2020 | 2019 | 2018 | 20172016 | 2015 | 2014 | 2013 | 2012 | 2011 2010 | 2009 | 2008 | 2007 | 2006 | 2005 | 2004 | 2003 | 2002 | 2001 | 2000 | 1999 | 1998

2024

256. “Peptide nucleic acid probe-assisted paper-based electrochemical biosensor for multiplexed detection of respiratory viruses.” Lomae, A., Teekayupak, K., Preechakasedkit, P., Pasomsub, E., Ozer, T., Henry, C.S., Citterio, D., Vilaivan, T., Chailapakul, O., Ruecha, N. Talanta 2024, DOI:10.1016/j.talanta.2024.126613

255. “Fill, Fold, Photo: Preconcentration and Multiplex Detection of Trace Level Heavy Metals in Water.” Aryal, P., Boes, J., Brack, E., Alexander, T., Henry, C.S. ACS Sensors 2024, DOI:10.1021/acssensors.4c01708

254. “Microfluidic paper-based analytical devices for simple and nondestructive durian fruit maturity assessment.” Mettakoonpitak, J., Chanthabun, A., Hatsakhun, P., Sirasunthorn, N., Siripinyanond, A., Henry, C.S. Analytica Chimica Acta 2024, DOI:10.1016/j.aca.2024.343252

253. “Application of chimeric antigens to paper-based diagnostics for detection of West Nile virus infections of Crocodylus porosus – A novel animal test case.” Johnston, R.A., Habarugira, G., Harrison, J.J., Isberg, S.R., Moran, J., Morgan, M.S., Davis, S.S., Melville, L., Howard, C.B., Henry, C.S., Macdonald, J., Bielefeldt-Ohmann, H., Hall, R.A., Hobson-Peters, J. Sensors and Actuators B: Chemical 2024, DOI:10.1016/j.snb.2024.136611

252. “Novel theranostic wounds dressing based on pH responsive alginate hydrogel/graphene oxide/levofloxacin modified silk.” Punnoy, P., Siripongpreda, T., Henry, C.S., Rodthongkum, N., Potiyaraj, P. International Journal of Pharmaceutics 2024, DOI:10.1016/j.ijpharm.2024.124406

251. “Size-dependent electrochemistry of laser-induced graphene electrodes.” Wirojsaengthong, S., Chailapakul, O., Tangkijvanich, P., Henry, C.S., Puthongkham, P. Electrochimica Acta 2024, DOI:10.1016/j.electacta.2024.144452

250. “Stability of Protein Pharmaceuticals: Recent Advances.” Manning, M.C., Holcomb, R.E., Payne, R.W., Stillahn, J.M., Connolly, B.D., Katayama, D.S., Liu, H., Matsuura, J.E., Murphy, B.M., Henry, C.S. & Crommelin, D.J.A.  Pharmaceutical Research 2024, DOI:10.1007/s11095-024-03726-x

249. “Automated enzyme-linked immunosorbent assay for point-of-care COVID-19 testing.” Baldo, T.A., Ataide, V.N., Park, J., Panraksa, Y., Martinez, B., Anderson, L.B.R., Malsick, L.E., Gallichotte, E.N., Ebel, G.D., Geiss, B.J., Dandy, D.S., Paixão, T.R.L.C., Henry, C.S. Electrochimica Acta 2024, DOI:10.1016/j.electacta.2024.144525

248. “Recent Trends in Nanomaterial Based Electrochemical Sensors for Drug Detection: Considering Green Assessment.” Ozer, T., Henry, C.S.  Current Topics in Medicinal Chemistry 2024, DOI:10.2174/0115680266286981240207053402

247. “Smartphone-enabled green anthocyanin sensor for Fe(III) sensing on paper using capillary-driven microfluidics.” Aryal, P., Indrianingsih, A.W., Henry, C.S.  Green Analytical Chemistry 2024, DOI:10.1016/j.greeac.2023.100091

246. “Multiplexed Capillary-Flow Driven Immunoassay for Respiratory Illnesses.” Link, J.S., O’Donnell-Sloan, J.J., Curdts, S., Geiss, B.J., Dandy, D.S., Henry, C.S.  Analytical Chemistry 2024, DOI:10.1021/acs.analchem.3c04977

245. “Capillary-driven microfluidic device integrating recombinase polymerase amplification for human papillomavirus detection.” Wisarut Khamcharoen, W., Siangproh, W., Henry, C.S., Sreamsukcharoenchai, N., Ratthawongjirakul, P., Chailapakul, O.  Sensors and Actuators B: Chemical 2024, DOI:10.1016/j.snb.2023.135016

244. “Electrochemical immunosensor for the quantification of galectin-3 in saliva.” Pittman, T.W., Zhang, X., Punyadeera, C., Henry, C.S.  Sensors and Actuators B: Chemical 2024, DOI:10.1016/j.snb.2023.134811

243. “Non-invasive iron deficiency diagnosis: a saliva-based approach using capillary flow microfluidics.” Prakobdi, C., Baldo, T.A., Aryal, P., Link, J.S., Saetear, P., Henry, C.S.  Analytical Methods 2024, DOI:10.1039/D3AY01933K

242. “Improving design features and air bubble manipulation techniques for a single-step sandwich electrochemical ELISA incorporating commercial electrodes into capillary-flow driven immunoassay devices.” Kaewarsa, P., Schenkel, M.S., Rahn, K.L., Laiwattanapaisal, W., Henry, C.S.  Analyst 2024, DOI:10.1039/D3AN01704D

241. “Microfluidics in environmental analysis: advancements, challenges, and future prospects for rapid and efficient monitoring.” Aryal, P., Hefner, C., Martinez, B., Henry, C.S.  Lab on a Chip 2024, DOI:10.1039/D3LC00871A

2023

240. Next-generation Electrochemical Sensors for Detection of Respiratory Viruses. Akdag, A., Seyman, D., Henry, C.S., Sagdic, O., Lomae, A., Ruecha, N., Vilaivan, T., Chailapakul, O., Ozer, T.  Sensors & Materials2023

239. “The use of Clitoria ternatea as sustainable detection tool for Ni (II) and Cu (II) ions in simple paper-based analytical device.” Indrianingsih, A.W., Aryal, P., Henry, C.S.  IOP Conference Series: Earth and Environmental Science 2023, DOI:10.1088/1755-1315/1267/1/012003

238. “Surface Modification of Thermoplastic Electrodes for Biosensing Applications via Copper-Catalyzed Click Chemistry.” Martinez, B.,Leroux, Y.R., Hapiot, P., Henry, C.S.  ACS Applied Materials & Interfaces 2023, DOI:10.1021/acsami.3c10013

237. “Versatile Technology for Tracking SARS-CoV-2 Bioshedding and Exposure in a Clinical-Care Setting.” Young, B.N., Gallichotte, E.N., Zier, L.B., Dunn, J., Alnachoukati, O., Nudell, N., Dobos, K.M., L’Orange, C., Quinn, C., Ebel, G.D., Henry, C.S., &amp Volckens, J.  ACS Environmental Science and Technology Letters2023, DOI:10.1021/acs.estlett.3c00611

236. “Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics.” Link, J.S., Carrell, C.S., Jang, I., Barstis, E.J.O., Bellows, R.A., O’Donnell-Sloan, J.J., Terry, J.S., Anderson, L.B.R., Panraska, Y., Geiss, B.J., Dandy, D.S., &amp Henry, C.S.  Analytica Chimica Acta2023, DOI:10.1016/j.aca.2023.341634

235. “Maximizing flow rate in single paper layer, rapid flow microfluidic paper-based analytical devices.” Briongos, I.M., Call, Z.D., Henry, C.S. &amp Bark Jr., D.L.  Microfluidics and Nanofluidics2023, DOI:10.1007/s10404-023-02679-8

234. “Fast and easy synthesis of silver, copper, and bimetallic nanoparticles on cellulose paper assisted by ultrasound.” Araya-Hermosilla, R., Martínez, J., Loyola, C.Z., Ramírez, S., Salazar, S., Henry, C.S., Lavín, R., Silva, N.  Ultrasonics Sonochemistry2023, DOI:10.1016/j.ultsonch.2023.106545

233. “Electrochemical Immunosensor for the Quantification of Galectin-3 in Salivas.” Pittman, T.W., Zhang, X., Punyadeera, C. & Henry, C.S.  Sensors and Actuators B: Chemical2023, DOI:/10.1016/j.snb.2023.134811

232. “Characterization of Factors Affecting Stripping Voltammetry on Thermoplastic Electrodes.” McMahon, C.J., Martinez, B., & Henry, C.S.  Journal of the Electrochemical Society2023, DOI:10.1149/1945-7111/acfa68

231. “Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics.” Link, J.S., Carrell, C.S., Jang, I., Barstis, E.J.O, Call, Z.D., Bellows, R.A., O’Donnell-Sloan, J.J., Terry, J.S., Anderson, L.B.R., Panraksa, Y., Geiss, B.J., Dandy, D.S., & Henry, C.S.  Analytica Chimica Acta2023, DOI: 10.1016/j.aca.2023.341634

230. “Microfluidic organotypic device to test intestinal mucosal barrier permeability ex vivo.” Cherwin, A.E., Templeton, H.N., Ehrlich, A.T., Patlin, B.H., Henry, C.S., & Tobet, S.A.  Lab on a Chip2023, DOI: 10.1039/D3LC00615H

230. “Application of Formulation Principles to Stability Issues Encountered During Processing, Manufacturing, and Storage of Drug Substance and Drug Product Protein Therapeutics.” Vitharana, S., Stillahn, J.M., Katayama, D.S., Henry, C.S., & Cornell Manning, M.  Journal of Pharmaceutical Sciences2023, DOI: 10.1016/j.xphs.2023.08.003

229. “Fast and easy synthesis of silver, copper, and bimetallic nanoparticles on cellulose paper assisted by ultrasound.” Araya-Hermosilla, R., Martínez, J., Zúñiga Loyola, C., Ramírez, S., Salazar, S., Henry, C.S., Lavín, R. & Silva, N.  Ultrasonics Sonochemistry2023, DOI: 10.1016/j.ultsonch.2023.106545

228. “Recent Advances of Optical Biosensors in Veterinary Medicine: Moving Towards the Point of Care Applications.” Amin, N., Almasi, A., Ozer, T., Henry, C.S., Hosseinzadeh, L. & Keshavarzi, Z.  Current Topics in Medicinal Chemistry2023, DOI: 10.2174/1568026623666230718163613

227. “Microfluidic paper-based analytical devices for simultaneous detection of oxidative potential and copper in aerosol samples” Mettakoonpitak, J., Sawatdichai, N., Thepnuan, D., Siripinyanond, A, Henry, C.S. & Chantara, S.  Theranostics2023, DOI: 10.1007/s00604-023-05819-7

226. “Saliva-based microfluidic point-of-care diagnostic” Pittman, T.W., Desci, D.B., Punyadeera, C. and Henry, C.S.  Microchimica Acta2023, DOI: 10.7150/thno.78872

2022

225. “Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2″ Clark, K.M., Schenkel, M.S., Pittman, T.W., Samper, I.C., Anderson, L.B.R., Khamcharoen, W., Elmegerhi, S., Perera, R., Siangproh, W., Kennan, A.J., Geiss, B.J., Dandy, D.S., and Henry, C.S.  ACS Measurement Science Au2022, DOI: 10.1021/acsmeasuresciau.2c00037

224. “A smartphone-assisted hybrid sensor for simultaneous potentiometric and distance-based detection of electrolytes” Phoonsawat, K., Agir, I., Dungchai, W., Ozer, T., and Henry, C.S.  Analytica Chimica Acta2022, DOI: 10.1016/j.aca.2022.340245

223. “1H-NMR Profiling of Short-Chain Fatty Acid Content from a Physiologically Accurate Gut-on-a-Chip Device” Martinez, B., Schwerdtfeger, L.A., Richardson, A., Tobet, S.A., and Henry, C.S.  Anal. Chem.2022, DOI: 10.1021/acs.analchem.1c05146

222. “Rapid prototyping of ion-selective electrodes using a low-cost 3D printed internet-of-things (IoT) controlled robot” Ozer, T., Agir, I., and Henry, C.S.  Talanta2022, DOI: 10.1016/j.talanta.2022.123544

221. “Progress toward a Simplified UTI Diagnostic: Pump-Free Magnetophoresis for E. coli Detection” Call, Z.D., Jang, I., Geiss, B.J., Dandy, D.S., and Henry, C.S.  Anal. Chem.2022, DOI: 10.1021/acs.analchem.2c00316

220. “Microfluidic-based ion-selective thermoplastic electrode array for point-of-care detection of potassium and sodium ions” Ozer, T. and Henry, C.S.  Microchimica Acta2022, DOI: 10.1007/s00604-022-05264-y

219. “Electrochemical Immunoassay for the Detection of SARS-CoV-2 Nucleocapsid Protein in Nasopharyngeal Samples” Samper, I.C., McMahon, C.J., Schenkel, M.S., Clark, K.M., Khamcharoen, W., Anderson, L.B.R., Terry, J.S., Gallichotte, E.N., Ebel, G.D., Geiss, B.J., Dandy, D.S., and Henry, C.S.  Anal. Chem.2022, DOI: 10.1021/acs.analchem.1c04966

218. “Colorimetric Paper-Based Analytical Device for Perfluorooctanesulfonate Detection” Menger, R., Beck, J.,Borch, T., and Henry, C.S.  ACS EST Water2022, DOI: 10.1021/acsestwater.1c00356

217. “An electrochemical paper-based analytical sensor for one-step latex protein detection.” Mettakoonpitak, J., Junkong, P., Saenonphut, A., Kwamman, T., Siripinyanond, A., and Henry, C.S.  Analyst2022, DOI: 10.1039/D1AN02067F

216. “Electrogenerated Chemiluminescent Detection of Polyamines on a Microfluidic Device Using Micromolded Carbon Paste Microelectrodes.” Gross, E., Lowry, E., Schaffer, L., and Henry, C.S.  Electroanalysis2022, DOI: 10.1002/elan.202100410

215. “Chemometric study of the Relative aggregation propensity of position 19 mutants of Aβ(1-42).” Zbacnik, N.J, Manning, M.C., and Henry, C.S.  Curr Protein Pept Sci2022, DOI: 10.2174/1389203723666220128105334

214. “Simultaneous Analysis of Ascorbic Acid, Uric Acid, and Dopamine at Bare Polystyrene Thermoplastic Electrodes.” McCord, C., Summers, B., and Henry, C.S.  ChemElectroChem2022, DOI: 10.1002/celc.202101600

2021

213. “All-solid state potassium-selective sensor based on carbon black modified thermoplastic electrode” Ozer, T. and Henry, C.S.  Electrochimica Acta2021, DOI: 10.1016/j.electacta.2021.139762

212. “User-friendly, magnetically sealed plug-and-play sensor module for online electrochemical sensing for fluidic devices” Roley, A., Clark, K., Richardson, A., Martinez, B., Tobet, S., Henry, C.S.  Chem Rxiv2021, DOI: 10.26434/chemrxiv-2021-tth3p

211. “Thermoplastic Electrode (TPE)-based Enzymatic Glucose Sensor Using Polycaprolactone-graphite Composites” Clark, K.M. and Henry, C.S.  Electronalysis2021, DOI: 10.1002/elan.202100446

210. “Disposable Passive Electrochemical Microfluidic Device for Diagnosis of Congenital Disorders of Glycosylation” Sierra, T., Henry, C.S., Crevillén, A.G., Escarpa, A.  Analysis & Sensing2021, DOI: 10.1002/anse.202100038

209. “Electrochemical Capillary-Flow Immunoassay for Detecting Anti-SARS-CoV-2 Nucleocapsid Protein Antibodies at the Point of Care” Samper, I. C., Sánchez-Cano A., Khamcharoen, W., Jang, I., Siangproh, W., Baldrich, A., Geiss, B. J., Dandy, D. S., Henry, C. S.  ACS Sensors2021, DOI: 10.1021/acssensors.1c01527

208. “A novel l-cysteine sensor using in-situ electropolymerization of l-cysteine: Potential to simple and selective detection” Khamcharoen, W., Henry, C. S., Siangproh, W.  Talanta2021, DOI: 10.1016/j.talanta.2021.122983

207. “Immobilization of Proteinase K for urine pretreatment to improve diagnostic accuracy of active tuberculosis” Panraska, Y., Amin, A., Graham, B., Henry, C. S., Chatterjee, D.  PLOS ONE2021, DOI: 10.1371/journal.pone.0257615

206. “High spatial resolution fluorescence imagery for optimized pest management within a Huanglongbing-infected citrus grove” Menger, R., Rehberg, R., Trivedi, P., Henry, C. S., Borch, T.  Phytopathology2021, DOI: 10.1094/PHYTO-05-21-0211-FI.

205. “Paper-based analytical devices for virus detection: Recent strategies for current and future pandemics” Ozer, T. and Henry, C. S.  Trends in Analytical Chemistry2021, DOI: 10.1016/j.trac.2021.116424

204. “Distance-Based Paper Device for a Naked-Eye Albumin-to-Alkaline Phosphatase Ratio Assay” Phoonsawat, K., Khachornsakkul, K., Henry C. S., Dungchai, W. ACS Sensors2021, DOI: 10.1021/acssensors.1c01058

203. “Thermoplastic Electrodes for Detection of Escherichia coli” Ozer, T.; McCord, C.; Geiss, B.; Dandy, D.; Henry, C.S.  Journal of the Electrochemical Society, 2021. DOI:10.1149/1945-7111/abf77e

202. “Plug-and-play assembly of paper-based colorimetric and electrochemical devices for multiplexed detection of metals” Silva-Neto, H.A.; Cardoso, T.M.G; McMahon, C. J.; Sgobbi, L.F.; Henry, C.S; Coltro, W.K.T. Analyst, 2021. DOI: 10.1039/d1an00176k

201. “Design and application of a self-pumping microfluidic staggered herringbone mixer” Channon, R.B., Menger, R.F., Wang, W., Carrao, D.B., Vallabhuneni, S., Kota, A.K., Henry, C.S. Microfluidics and Nanofluidics, 2021, 25 (31). DOI: 10.1007/s10404-021-02426-x

200. “Sensors for Detecting Per- and Polyfluoroalkyl Substances (PFAS): A Critical Review of Development Challenges, Current Sensors, and Commercialization Obstacles” Menger, R.F., Funk, E., Henry, C.S., Borch, T. Chemical Engineering Journal2021, DOI: 10.1016/j.cej.2021.129133

199. “Highly selective simultaneous Cu(II), Co(II), Ni(II), Hg(II), Mn(II) determination in water samples on microfluidic paper-based analytical devices” Kamnoet, P. Aeungmaitrepirom, W., Menger, R.F., Henry, C.S. Analyst2021, DOI: 10.1039/D0An02200D

198. “Simple Biodegradable Plastic Screen-Printing for Microfluidic Paper-Based Analytical Devices” Mettakoonpitak, J., Khongsoun, K., Wongwan, N., Kaewbutdee, S., Siripinyanond, A., Kuharuk, A., Henry, C.S. Sensors and Actuators B: Chemical2021, DOI: 10.1016/j.snb.2021.129463

197. “Thermoplastic electrodes as a new electrochemical platform coupled to microfluidic devices for tryptamine determination” Pradela-Filho, L.A., Araujo, D.A.G., Takeuchi, R.M., Santos, A.L., Henry, C.S. Analytica Chimica Acta2021, DOI: 10.1016/j.aca.2020.12.059

 

2020

196. “SECM Investigation of Carbon Composite Thermoplastic Electrodes” Berg, K.E., Leroux, Y.R., Hapiot, P., Henry, C.S. Analytical Chemistry2020, DOI: 10.1021/acs.analchem.0c01041

195. “Electrochemical paper-based analytical device for multiplexed, point-of-care detection of cardiovascular disease biomarkers” Boonkaew, S., Jang, I., Noviana, E., Siangproh, W., Chailapakul, O., Henry, C.S. Sensors and Actuators B: Chemical, 2020, DOI: 10.1016/j.sng.2020.129336

194. “A facile one-step gold nanoparticles enhancement based on sequential patterned lateral flow immunoassay device for C-reactive protein detection” Panraksa, Y., Apilux, A., Jampasa, S., Puthong, S., Henry, C.S., Rengpipat, S., Chailapakul, O. Sensors and Actuators B: Chemical2020, DOI: 10.1016/j.snb.2020.129241

193. “Dual sample Preconcentration for Simultaneous Quantification of Metal Ions Using Electrochemical and Colorimetric Assays” Ninwong, B., Ratnarathorn, N., Henry, C.S., Mace, C.R., Dungchai, W. ACS Sensors2020, DOI: 10.1021/acssensors.0c01793

192. “Fluorescent Dye Paper-Based Method for Assessment of Pesticide Coverage on leaves and Trees: A Citrus Grove Case Study” Menger, R.F., Bontha, M. Beveridge, J.R., Borch, T., Henry, C.S. Journal of Agricultural and Food Chemistry2020, DOI: 10.1021/acs.jafc.0c01835

191. “Paper-Based Pump-Free Magnetophoresis”  Call, Z., Carrell, C., Jang, I., Geiss, B., Dandy, D., Henry, C.S. Analytical Methods2020, DOI: 10.1039/DoAY1523G

 190. “NFC-enabling Smartphone-based Portable Amperometric Immunosensor for Hepatitis B Virus Detection” Teengam, P., Siangproh, W., Tontisirin, S., Jiraseree-amornkun, A., Chuaypen, N., Tangkijvanich, P., Henry, C.S., Ngamrojanavanich, N., Chailapakul, O. Sensors and Actuators B: Chemical2020, DOI: 10.1016/j.snb.2020.12885

189. “Point-of-Need Disposable ELISA System for COVID-19 Serology Testing” Carrell, C., Link, J., Jang, I., Terry, J., Scherman, M., Call, Z., Panraksa, Y., Dandy, D.S., Geiss, B.J., Henry, C.S. ChemRXiV2020

188. “Exploring carbon particle type and plasma treatment to improve electrochemical properties of stencil-printed carbon electrodes” Kava, A.A., Henry, C.S. Talanta2020, DOI: 10.1016/j.talanta.2020.121553

187. “Flow Control in a Laminate Capillary-Driven Microfluidic Device” Jang, I., Kang, H., Song, S., Dandy, D.S., Geiss, B.J., Henry, C.S. ChemRxiv2020.

186. “Pump-Free Microfluidic Rapid Mixer Combined with a Paper-Based Channel” Jang, I., Carrao, D., Menger, R., de Oliveira A.R., Henry, C.S., ACS Sensors2020, DOI: 10.1021/acssensors.0c00937

185. “Micromolded Carbon Paste Microelectrodes for Electrogenerated Chemiluminescent Detection on Microfluidic Devices” Gross, E.M., Porter, L.R., Stark, N.R., Lowry, E.R., Schaffer, L.V., Maddipati, S.S., Hoyt, D.J., Stombaugh, S.E., Peila, S.R., Henry, C.S. ChemElectroChem2020, DOI:  10.1002/celc.202000366
*The article above was featured on the cover of ChemElectroChem.*

184. “Viscosity Measurements Utilizing a Fast-Flow Microfluidic Paper-Based Device” Jang, I. Berg, K.E., Henry, C.S., Sensors and Actuators B: Chemical2020, 319, 128240. 

183. “Sealing 3D-printed parts to poly(dimethylsiloxane) for simple fabrication of microfluidic devices” Carrell, C.D., McCord, C.P, Wydallis, R.M., Henry, C.S. Analytica Chimica Act2020, DOI: 10.1016/j.aca.2020.05.014

182. “Paper-based nuclease protection assay with on-chip sample pretreatment for point-of-need nucleic acid detection” Noviana, E., Jain, S., Hostetter, J., Geiss, B.J., Dandy, D.S., Henry, C.S. Analytical and Bioanalytical Chemistry2020, 412, 3051-3061.

181. “Emerging Applications of Paper-Based Analytical Devices for Drug Analysis: A Review” Noviana, E., Blascke Carroao, D., Pratiwi, R., Henry, C.S. Analytical Chimica Acta2020, DOI: 10.1016/j.aca.2020.03.013
*The article above was featured on the cover of Analytical Chimica Acta.*

180. “Sensitive distance-based paper-based quantification of mercury ions using carbon nanodots and heating-based preconcentration” Ninwong, B., Sangkaew, P., Hapa, P., Ratnarathorn, N., Menger, R.F., Henry, C.S., Dunchai, W. RSC Advances. 2020, 10(17), 9884-9893.

179. “Simultaneous Electrochemical Detection in Paper-Based Analytical Devices” Noviana, E., Henry, C.S. Current Opinion in Electrochemistry2020, DOI: 10.1016/j.coelec.2020.02.013

178. “Advances in Paper-Based Analytical Devices” Ozer, T., McMahon, C., Henry, C.S., Annual Review of Analytical Chemistry. 2020, 13(1), 15-19.

177. “Dynamic classification of personal microenvironments using a suite of wearable, low-cost sensors” Quinn, C., Anderson, B.G., Magzamen, S., Herny, C.S., Volckens, J. Journal of Exposure Science & Environmental Epidemiology. 2020, DOI: 10.1038/s41370-019-019802

176. “Rapid Analysis in Continuous Flow Electrochemical Paper-Based Analytical Devices” Pradela-Filho, L.A., Noviana, E., Araujo, D., Takeuchi, R., Santos, A., Henry, C.S. ACS Sensors2020, 5(1), 274-281.

175. “Chemical and Biological Sensors for Viral Detection” Ozer, T., Geiss, B.J., Henry, C.S. Journal of The Electrochemical Society, 2020, 167(3).

174. “A microfluidic organotypic device for culture of mammalian intestines ex vivo” Richardson, A., Schwerdtfeger, L.A., Eaton, D., Mclean, I., Henry, C.S., Tobet, S.A. Analytical Methods2020, DOI: 10.1039/C9AY02038A

173. “Electrochemical paper-based devices: sensing approaches and progress toward practical applications” Noviana, E. McCord, C.P., Clark, K.M., Jang, I., Henry, C.S. Lab on a Chip, 2020, 20(1), 9-34.
*The article above was featured on the cover of Lab on a Chip.*

 

2019

172. “Disposable Glassy Carbon Stencil Printed Electrodes for Trace Detection of Cadmium and Lead” Kava, A.A., Beardsley, C., Hofstetter, J., Henry, C.S. Analytica Chimica Acta2019, 1103, 58-66.

171. “Janus Electrochemical Paper-Based Analytical Devices for Metals Detection in Aerosol Samples” Mettakoonpiak, J., Volckens, J., Henry, C.S. Analytical Chemistry, 2019, 1056, 88-95.

170. “High-throughput, semi-automated dithiothreitol (DTT) assays for oxidative potential of fine particular matter” Berg, K.E., Clark, K.M., Li, X., Carter, E.M., Volckens, J., Henry, C.S. Atmospheric Environment, 2019, 222, 117-132.

169. “Read-by-eye quantification of aluminum (III) in distance-based microfluidic paper-based analytical devices” Nguyen, M.P., Kelly, S. P., Wydallis, J.B., Henry, C.S. Analytica Chimica Acta2019, 1100, 156-162.

168. “Anodic stripping voltammetric determination of lead and cadmium with stencil-printed transparency electrodes” Alvarez-Martos, I. Henry, C.S., Abedul, M.T.F, Laboratory methods in Dynamic Electroanalysis2020, DOI: 10.1016/B978-0-12-815932-3.00004-8

167. “USB powered microfluidic paper-based analytical devices” Schaumburg, F., Kler, P.A., Carrell, C.S., Berli, C.L.A., Henry, C.S. Electrophoresis2019, 0, 1-8.

166. “A Chemometric Approach Toward Predicting the Relative Aggregation Propensity: Ab (1-42)” Zbacnik, NJ, Henry, C.S., Manning, M.C., Journal of Pharmaceutical Sciences2019, 109, 624-632.

165. “Increasing Applications of Graphite Thermoplastic Electrodes with Aryl Diazonium Grafting” Berg, K.E., Leroux, Y.R., Hapiot, P., Henry, C.S., ChemElectroChem20196, 4811 – 4816. 

164. “Polycaprolactone-enabled sealing and carbon composite electrode integration into electrochemical microfluidics” Klunder, K.J., Clark, K.M., McCord, C., Berg, K.E., Minteer, S.D., Henry, C.S. Lab on a Chip2019, 19, 2589 – 2597.

163. “Rapid Bacteria Detection at Low Concentrations Using Sequential Immunomagnetic Separation and Paper-Based Isotachophoresis” Shaumburg, F., Carrell, C.S., Henry, C.S. Analytical Chemistry2019, 91, 9623-9630.

162. “Superomniphobic Papers for On-Paper pH Sensors” Movafaghi, S., Cackovic, M., Wang, W., Vahabi, H., Pendurthi, A., Henry, C.S., Kota, A.K. Advanced Materials Interfaces2019, 6(13), 1900232. 

161. “Multilayered Microfluidic Paper-Based Devices: Characterization, Modeling, and Perspectives” Channon, R.B., Nguyen, M.P., Henry, C.S., Dandy, D.S. Analytical Chemistry, 201991, 8966 – 8972.

160. “Oxidative potential of diesel exhaust particles: role of fuel, engine load, and emissions control” Sharma, N. Vanderheyden, C. Henry, C.S., Volckens, J., Jathar, S.H. Environmental Science: Processes & Impacts, 2019, 21, 819 – 830. 

159. “A nuclease protection ELISA assay for colorimetric and electrochemical detection of nucleic acids” Filer, J.E., Channon, R.B, Henry, C.S., Geiss, B.J. Analytical Methods2019, 11, 1027 – 1034. 

158. “An Ultra-sensitive Capacitive Microwire Sensor for Pathogen-Specific Serum Antibody Responses” Wang, L., Filer, J.E., Lorenz, M.M., Henry, C.S., Dandy, D.S., Geiss, B.J. Biosensors and Bioelectronics2019, 131, 46-52. 

157. “Janus Electrochemistry: Simultaneous Electrochemical Detection at Multiple Working Conditions in a Paper-based Analytical Device” Nantaphol, S., Kava, A.A., Channon, R.B., Kondo, T., Siangproh, W., Chailapakul, O., Henry, C.S. Analytica Chimica Acta2019, 1056, 88-95. 

156. “Electrochemical Dithiothreitol Assay for Large-Scale Particulate Matter Studies” Berg, K.E., Turner, L.R., Benka-Coker, M.L., Rajkumar, S., Young, B.N., Peel, J.L., Clark, M.L., Volckens, J., Henry, C.S. Aerosol Science and Technology2019, 53, 268 – 275. 

155.”Rotary manifold for automating a paper-based Salmonella immunoassay” Carrell, C.S., Wydallis, R.M., Bontha, M., Boehle, K.E., Beveridge, J.R., Giess, B.J., Henry, C.S. RSC Advances2019, 9, 29078-29086.

154. “Thermoplastic Electrode Arrays in Electrochemical Paper-Based Analytical Devices” Noviana, E., Klunder, K.J., Channon, R.B., Henry, C.S. Analytical Chemistry2019, 91, 2431-2438. 

 

2018

153. “Single board computing system for automatic colorimetric analysis on low-cost analytical devices” Boehle, K.E., Doan, E., Henry, S., Beveridge, J.R., Pallickara, S.L., Henry, C.S. Analytical Methods2018, 10, 5282-5290.

152. “Beyond the Lateral Flow Assay: A Review of Paper-based Microfluidics” Carrell, C.S., Kava, A., Nguyen, M.P., Menger, R.F, Munshi, Z., Call, Z., Nussbaum, M., Henry, C.S. Microelectronic Engineering2018, 206, 45-54.

151. “Critical Components and Innovations in Paper-Based Analytical Devices”  Channon, R.B., Srisa-Art, M., Boehle, K., Henry, C.S. Paper-based Diagnostics, 2018, DOI: 10.1007/978-3-319-96870-4_3

150. “Electrochemical impedance-based DNA sensor using pyrrolidinyl peptide nucleic acids for tuberculosis detection” Teengam, P., Siangproh, W., Tuantranont, A.,  Vilaivan, T., Chailapakul, O.,  Henry, C. S.,  Anal. Chim. Acta, 2018, DOI: 10.1016/j.aca.2018.07.045

149. “Distance–based Paper Sensor for Determination of Chloride ion Using Silver Nanoparticles” Phoonsawat, K., Ratnarathorn, N., Henry C. S., Dungchai, W., Analyst, 2018, DOI: 10.1039/C8AN00670A

148. “Electrophoretic Separations on Parafilm-Paper-Based Analytical Devices” Mettakoonpitak J., Henry, C. S., Sensors and Actuators B, 2018, 273, 1022-1028.

147. “Microfluidic devices containing thin rock sections for oil recovery studies” Gerold C. T., Krummel, A. T., Henry, C. S., Microfluid. Nanofluid., 2018, 22, 7, 76

146. “Detection of Analgesics and Sedation Drugs in Whiskey using Electrochemical Paper‐Based Analytical Devices” Dias, A. A., Cardoso, T. M. G., Chagas, C. L. S., Oliveira, V. X. G., Munoz, R. A. A., Henry, C. S., Santana, M. H. P., Paixão, T. R. L. C., Coltro, W. K. T., Electroanalysis2018, DOI: 10.1002/elan.201800308

** The above article was featured on the cover of Electroanalysis.**

145. “Paper-Based Enzyme Competition Assay for Detecting Falsified β-Lactam Antibiotics ” Boehle, K. E., Carrell, C. S., Caraway, J., Henry, C. S., ACS Sens., 2018, DOI: 10.1021/acssensors.8b00163

144. “Development of an Electrochemical Paper-Based Analytical Device for Trace Detection of Virus Particles” Channon, R. B., Yang, Y., Feibelman, K. M., Geiss, B. J., Dandy, D. S., Henry, C. S., Anal. Chem., 2018, DOI: 10.1021/acs.analchem.8b02042

143. “Quantitative Colorimetric Paper Analytical Devices Based on Radial Distance Measurements for Aqueous Metal Determination” Hofstetter, J., Wydallis, J., Neymark, G., Thomas, T., Harrington, J., Henry, C. S., Analyst2018,  DOI: 10.1039/C8AN00632F

142. “High throughput detection of deamidation using S-(5′-adenosyl)-l-homocysteine hydrolase and a fluorogenic reagent” Murphy, B. M.; Ozumerzifona, T. J.; Henry, C. S.; Manning, M. C., J. Pharm. Biomed. Anal., 2018, 156, 323–327

141. “Denaturation and Aggregation of Interferon-τ in Aqueous Solution” Manning, R. R., Wilson, G. A., Holcomb, R. E., Zbacnik, N. J., Tellechea, A. A., Gilley-Dunn, C. L., Krammes, R. J., Krammes, N. S., Evans, G. J., Henry, C. S., Manning. M. C., Murphy, B. M., Payne, R. W., Katayama, D. S., Pharm. Res., 2018, 35:137, DOI: 10.1007/s11095-018-2418-1

140. “Powering Ex Vivo Tissue Models in Microfluidic Systems” Mclean, I.; Schwerdtfeger, L. A.; Tobet, S. A.; Henry, C. S., Lab Chip2018, DOI: 10.1039/C8LC00241J

139. “Electrochemical Biosensor System Using A CMOS Microelectrode Array Provides High Spatially and Temporally Resolved Images” Tedjo, W.; Nejad, J. E.; Feeny, R.; Yang, L.; Henry, C. S.; Tobet, S. A.; Chen, T., Biosens. Bioelectron., 2018, DOI: https://doi.org/10.1016/j.bios.2018.04.009

138. “Development of Paper Based Analytical Devices for Minimizing the Viscosity Effect in Human Saliva” Noiphung, J.; Nguyen, M. P.; Punyadeera, C.; Wan, Y.; Laiwattanapaisal, W.; Henry, C. S.; Theranostics2018, 8(14), 3797-3807

137. “Dip-and-read” paper-based analytical devices using distance-based detection with colour screening” Yamada, K.; Citterio, C.; Henry C. S., Lab Chip, 2018,  DOI: 10.1039/C8LC00168E

136. “Selective Distance-Based K+ Quantification on Paper-Based Microfluidics” Gerold, C. T.; Bakker, E.; Henry, C. S., Anal. Chem., 2018, 90 (7), 4894–4900

135. “IR-Compatible PDMS microfluidic devices for monitoring of enzyme kinetics” Srisa-Art, M.; Noblitt, S. D.; Krummel, A. T.; Henry, C. S., Anal. Chim. Acta, 2018, 1021, 95-102

134. “Solid-Phase Extraction Coupled to a Paper-Based Technique for Trace Copper in Drinking Water” Quinn, C. W.; Cate, D.; Miller-Lionberg, D.; Reilly, T.; Volckens, J.; Henry, C. S., Environ. Sci. Technol. 2018, 52, 6, 3567-3573

133. “Rapid Flow in Multilayer Microfluidic Paper-Based Analytical Devices” Channon, R. B.; Nguyen, M. P.; Scorzelli, A. G.; Henry, E. M.; Volckens, J.; Dandy, D. S.; Henry, C. S., Lab Chip, 2018, 18, 793-802

132. “Design considerations for reducing sample loss in microfluidic paper-based analytical devices” Nguyen, M. P.; Meredith, N. A.; Kelly, S. P.; Henry, C. S., Anal. Chim. Acta2018, 1017, 20-25

131. “Highly transparent tetraaminophthalocyanine polymer films for DSSC cathodes” Klunder, K. J.; Elliot. M. C.; Henry, C. S., J. Mater. Chem. A, 2018, 6, 2767-2774 

130. “An Instrument-free Detection of Antioxidant Activity Using Paper-based Analytical Devices Coated with Nanoceria” Piyanan, T.; Athipornchai, A.; Henry, C. S.; Sameenoi, Y., Anal. Sci., 2018, 34, (1), 97-102

129. “Observation of dynamic surfactant adsorption facilitated by divalent cation bridging” Gerold, C. T.; Henry, C. S., Langmuir, 2018, 34 (4), 1550–1556

128. “Laminated and infused Parafilm® − paper for paper-based analytical devices,” Shin Kin, Y.; Yang, Y.; Henry, C. S., Sens. Act. B., 2018, 255, (3), 3654-3661

127. “Highly Sensitive Detection of Salmonella typhimurium Using a Colorimetric Paper Based Analytical Device Coupled with Immunomagnetic Separation,” Srisa-Art, M.; Boehle, K. E.; Geiss, B. J.; Henry, C. S., Anal. Chem.,2018, 90 (1), 1035-1043. 

 

2017

126. “Low-cost reusable sensor for cobalt and nickel detection in aerosols using adsorptive cathodic square-wave stripping voltammetry,” Mettakoonpitak, J.; Miller-Lionberg, D.; Reilly, T.; Volckens, J.; Henry, C. S., J. Electroanal. Chem., 2017, 805, 75-82.

125. “Patternable Solvent-Processed Thermoplastic Graphite Electrodes,” Klunder, K. J.; Nilsson, Z.; Sambur, J.; Henry, C. S., J. Am. Chem. Soc.2017139 (36), 12623–12631

124. “A Paper-Based Colorimetric Spot Test for the Identification of Adulterated Whiskeys,” Cardoso, T. M. G.; Channon, R. B.; Adkins, J. A.; Talhavini, M.; Coltro, W. K. T.; Henry, C. S., Chem. Comm, 201753 (56), 7957-7960.

123. “A Selective Distance-Based Paper Analytical Device for Copper (II) Determination Using a Porphyrin Derivative,” Pratiwi, R.; Nguyen, M. P.; Ibrahim, S.; Yoshioka, N.; Henry, C. S.; Tjahjono, D. H. Talanta, 2017, 174, 493-499. 

122. “Point-of-Need Simultaneous Electrochemical Detection of Lead and Cadmium Using Low-Cost Stencil-Printed Transparency Electrodes,” Martin-Yerga, D.; Alvarez-Martex, I.; Blanco-Lopez, M. C.; Henry, C. S.; Fernandez-Abedul, M. T. Anal. Chim. Acta, 2017981, 24-33.

121. “Utilizing Paper-Based Devices for Antimicrobial Resistant Bacteria Detection,” Boehle, K.E.; Gilliand, J.; Wheeldon, C.R.; Adkins, J.A.; Geiss, B.J.; Ryan, E. P.; Henry, C. S. Angew. Chem. Int. Ed., 2017, 56 (24), 6886-6890.

120. “Multiplex Paper-Based Colorimetric DNA Sensor Using Pyrrolidinyl Peptide Nucleic Acid-Induced AgNPs Aggregation for Detecting MERS-CoV, MTB, and HPV Oligonucleotides,” Teengam, P.; Siangproh, W.; Tuantranont, A.; Vilaivan, T.; Chailapakul, O.; Henry, C. S. Anal. Chem., 2017, 89, 5428-5435.

119. “Versatile Fabrication of Paper-Based Microfluidic Devices with High Chemical Resistance Using Scholar Glue and Magnetic Masks,” Cardoso, T. M. G.; de Souza, F. R.; Garcia, P. T.; Rabelo, D.; Henry, C. S.; Coltro, W. K. T. Anal. Chim. Acta, 2017, 974, 63-68.

118. “Boron Doped Diamond Paste Electrodes for Microfluidic Paper-Based Analytical Devices,” Nantaphol, S.; Channon, R. B.; Kondo, T.; Siangproh, W.; Chailapakul, O.; Henry, C. S. Anal. Chem., 2017, 89, 4100-4107.

117. “Colorimetric and Electrochemical Bacteria Detection Using Printed Paper- and Transparency-Based Analytic Devices,” Adkins, J. A.; Boehle, K.; Friend, C.; Chamberlain, B.; Bisha, B.; Henry, C. S. Anal. Chem., 2017, 89, 3613-3621.

**The above article was featured in the American Chemical Society weekly press packet, resulting in online and local news coverage**

116. “Role of Buffers in Protein Formulations,” Zbacnik, T. J.; Holcomb, R. E.; Katayama, D. S.; Murphy, B. M.; Payne, R. W.; Coccaro, R. C.; Evans, G. J.; Matsuura, J. E.; Henry, C. S.; Manning, M. C. J. Pharm. Sci., 2017, 106, 713-733.

115. “Electrochemical paper-based peptide nucleic acid biosensor for detecting human pipillomavirus,” Teengam, P.; Siangproh, W.; Tuantranont, A.; Henry, C. S.; Vilaivan, T; Chailapakul, O. Anal. Chim. Acta, 2017, 952, 32-40.

114. “Paper-based microfluidics for experimental design: screening masking agents for simulataneous determination of Mn (II) and Co (II),” Meredith, N.A.; Volckens, J.; Henry, C. S. Anal. Meth., 2017, 9 (3), 534-540.

113. “Paper-Based Microfluidic Devices: Emerging Themes and Applications,” Yang, Y.; Noviana, E.; Nguyen, M. P.; Geiss, B. J.; Dandy, D. S.; Henry, C. S. Anal. Chem., 2017, 89 (1), 71-91.

112. “AgNP/Bi/Nafion‐modified Disposable Electrodes for Sensitive Zn (II), Cd (II), and Pb (II) Detection in Aerosol Samples,” Mettakoonpitak, J.; Mehaffy, J., Volckens, J.; Henry, C. S. Electroanalysis, 2017, 29 (3), 880-889.

111. “Development and evaluation of an ultrasonic personal aerosol sampler,” Volckens, J.; Quinn, C.; Leith, D.; Mehaffy, J.; Henry, C. S.; Miller-Lionberg, D. Indoor Air, 2017, 27 (2),  409-416.

 

2016

110. “Development of a Quasi-Steady Flow Electrochemical Paper-Based Analytical Device,” Adkins, J.A.; Noviana, E.; Henry, C. S. Anal. Chem., 2016, 88, 10639-10647.

109. “Electrochemistry on Paper‐based Analytical Devices: A Review,” Mettakoonpitak, J.; Boehle, K.; Nantaphol, S.; Teengam, P.; Adkins, J.A.; Srisa-Art, M; Henry, C. S. Electroanalysis, 2016, 28, 1420-1436.

108. “Graphene-polyaniline modified electrochemical droplet-based microfluidic sensor for high-throughput determination of 4-aminophenol,” Rattanarat, P.; Suea-Ngam, A.; Ruecha, N.; Siangproh, W; Henry, C. S.; Srisa-Art, M.; Chailapakul, O. Anal. Chim. Acta, 2016, 925, 51-60.

107. “Label-free detection of C-reactive protein using an electrochemical DNA immunoassay,” Songjaroen, T; Feeny, R. M.; Mensack, M. M.; Laiwattanapaisal, W.; Henry, C. S., Sensing and Bio-Sensing Research, 2016, 8, 14-19.

106. “Characterizing nonconstant instrumental variance in emerging miniaturized analytical techniques,” Noblitt, S. D.; Berg, K. E.; Cate, D. M.; Henry, C. S. Anal. Chim. Acta, 2016, 915, 64-73.

105. “Degassed PDMS pump for controlled extraction from dried filter samples in microfluidic devices,” Feeny, R. M.; Puissant, N. L.; Henry, C. S. Anal. Meth., 2016, 8, 8266-8271.

104. “Paper-based analytical devices for environmental analysis,” Meredith, N. A.; Quinn, C.; Cate, D. M.; Reilly, T. H.; Volckens, J.; Henry, C. S. Analyst, 2016, 141, 1874-1887.

103. “Pesticide analysis using nanoceria-coated paper-based devices as a detection platform,” Nouanthavong, S.; Nacapricha, D.; Henry, C. S.; Sameenoi, Y., Analyst, 2016, 141, 1837-1846.

102. “Stability of lyophilized teriparatide, PTH(1-34), after reconstitution,” Merutka, G.; Murphy, B. M.; Payne, R. W.; Wilson, G. A.; Matsuura, J. E.; Henry, C. S.; Manning, M. C., Eur. J. Pharm. Biopharm., 2016, 99, 84-93.

101. “Fabrication of IR-transparent microfluidic devices by anisotropic etching of channels in CaF2,” Lehmkuhl, B.; Noblitt, S. D.; Krummel, A. T.; Henry, C. S., Lab Chip, 2015, 15, 4364-4368.

100. “Manganese Detection Using Stencil-Printed Carbon Ink Electrodes on Transparency Film,” Berg, K. E.; Adkins, J. Al; Boyle, S. E.; Henry, C. S., Electroanalysis, 2016, 28, 679-684.

 

2015

99. “Spatiotemporal norepinephrine mapping using a high-density CMOS microelectrode array,” Wydallis, J. B.; Feeny, R. M.; Wilson, W.; Kern, T.; Chen, T.; Tobet, S.; Reynolds, M. M.; Henry, C. S., Lab Chip, 2015, 15, 4075-4082.

98. “Development of electrochemical paper-based glucose sensor using cellulose-4-aminophenylboronic acid-modified screen-printed carbon electrode,” Rungsawang, T.; Punrat, E.; Adkins, J.; Henry, C.; Chailapakul, O., Electroanalysis, 2016, 28, 462-468.

97. “Electrochemical detection in paper-based analytical devices using microwire electrodes,” Adkins, J. A.; Henry, C. S., Anal. Chim. Acta, 2015, 891, 247-254.

96. “Calibration-free quantitation in microchip zone electrophoresis with conductivity detection,” Noblitt, S. D.; Henry, C. S., Electrophoresis, 2015, 36, 1927-1934.

95. “Multiplexed paper analytical device for quantification of metals using distance-based detection,” Cate, D. M.; Noblitt, S. D.; Volckens, V.; Henry, C. S., Lab Chip, 2015, 15, 2808-2818.

94. Pseudomonas moraviensis subsp. stanleyae, a bacterial endophyte of hyperaccumulator Stanleya pinnata, is capable of efficient selenite reduction to elemental selenium under aerobic conditions,” Staicu, L. C.; Ackerson, C. J.; Cornelis, P.; Ye, L.; Berendsen, R. L.; Hunter, W. J.; Noblitt, S. D.; Henry, C. S.; Cappa, J. J.; Monenieri, R. L.; Wong, A. O.; Musilova, L.; Novakova, M.; van Hullebusch, E. D.; Lens, P. N. L.; Reynolds, J. R. B.; Pilon-Smits, E. A. H., J. Appl. Microbio., 2015, 119, 400-410.

93. “Electrochemical Paper-Based Microfluidic Devices,” Adkins, J.; Boehle, K.; Henry, C. S., Electrophoresis, 2015, 36, 1811-1824.

92. “Sensitive electrochemical sensor using a graphene–polyaniline nanocomposite for simultaneous detection of Zn(II), Cd(II), and Pb(II),” Ruecha, N.; Rodthongkum, N.; Cate, D.M.; Volckens, J.; Chailapakul, O.; Henry, C.S., Anal. Chim. Acta, 2015, 874, 40-48.

91. “Recent Advances in Paper-Based Microfluidic Devices,” Cate, D. M.; Adkins, J. A.; Mettapoonpitak, J.; Henry, C. S., Anal. Chem., 2015, 87, 19-41.

90. “Analysis of Nitric Oxide from Chemical Donors Using CMOS Platinum Microelectrodes,” Feeny, R. M.; Wydallis, J. B.; Lantvit, S.; Chen, T.; Reynolds, M. M.; Tobet, S.; Henry, C. S., Electroanalysis, 2015, 27, 1104-1109.

 

2014

89. “Orthogonal Methods To Size Exclusion Chromatography (Sec) For Quantitation And Characterization Of Protein Aggregates,” Manning, R; Holcomb, R.; Wilson, G.; Henry, C. S.; Manning, M., BioPharm International, 2014, December, 32-39.

88. “One-Step Polymer Screen-Printing for Microfluidic Paper-Based Analytical Device (mPAD) Fabrication,” Sameenoi, Y.; Nongkai, P. N.; Nouanthavong, S.; Henry, C. S.; Nacapricha, D., Analyst, 2014, 139, 6580-6588.

87. “Sensitive, Selective Analysis of Selenium Oxoanions Using Microchip Electrophoresis with Contact Conductivity Detection,” Noblitt, S. D.; Staicu, L. C.; Ackerson, C. J.; Henry, C. S., Anal. Chem., 2014, 86, 8425-8432.

86. “A simple microfluidic electrochemical HPLC detector for quantifying Fenton reactivity from welding fumes,” Pluangklang, T.; Wydallis, J. B.; Cate, D. M.; Nacapricha, D.; Henry, C. S., Anal. Methods, 2014, 6, 8180-8186.

85. “Low cost, simple three dimensional electrochemical paper-based analytical device for determination of p-nitrophenol,” Santhiago, M.; Henry, C. S.; Kubota, C. S., Electrochim. Acta, 2014, 130, 771-777.

84. “Multilayer Paper-Based Device for Colorimetric and Electrochemical Quantification of Metals,” Rattanarat, P.; Dungchai, W.; Cate, D. M..; Volckens, J.; Chailapakul, O.; Henry, C. S., Anal. Chem., 2014, 86, 3555-3562.

83. “Laboratory Evaluation of a Microfluidic Electrochemical Sensor for Aerosol Oxidative Load,” Koehler, K.; Shapiro, J.; Sameenoi, Y.; Henry, C. S.; Volckens, J., Aerosol Sci. Tech., 2014, 48, 489-497.

82. “Rapid Detection of Transition Metals in Welding Fumes Using Paper-Based Analytical Devices,” Cate, D.; Nanthasurasak, P.; Riwkulkajorn, P.; L’Orange, C.; Henry, C. S.; Volckens, J., Ann. Occup. Health2014, 58, 413-423.

81. “Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water,” Adkins, J.; Gertsch, J.; Chanchand, J.; Perezmendez, A.; Coleman, S.; Osbodio, A.; Henry, C.; Goodridge, L.; Bisha, B. JOVE, 2014, Jun 9;(88). doi: 10.3791/51414.

 

2013

80. “Determination of aerosol oxidative activity using silver nanoparticle aggregation on paper-based analytical devices,” Dungchai, W.; Sameenoi, Y.; Chailapakul, O.; Volckens, J.; Henry, C. S., Analyst2013,138, 6766-6773.

79. “A microfluidic paper-based analytical device for rapid quantification of particulate chromium,” Rattanarat, P.; Dungchai, W.; Cate, D. M.; Siangproh, W.; Volckens, J.; Chailapakul, O.; Henry, C. S., Anal. Chim. Acta2013, 800, 50-55.

78. “Electrochemical detection of glucose from whole blood using paper-based microfluidic devices,” Noiphung, J.; Songjaroen, T.; Dungchai, W.; Henry, C.; Chailapakul, O.; Laiwattanapaisal, W., Anal. Chim. Acta2013, 788, 39-45.

77. “Simple, Distance-Based Measurement for Paper Analytical Devices,” Cate, D. M.; Dungchai, W.; Cunningham, C. J.; Volckens, J.; Henry, C. S., Lab Chip2013, 2397-2404.

76. “Construction and Electrochemical Characterization of Microelectrodes for Improved Sensitivity in Paper-Based Analytical Devices,” Santhiago, M.; Wydallis, J.; Kubota, L. T.; Henry, C. S., Anal. Chem.2013, 85, 5233-5239.

75. “Microfluidic Paper-Based Analytical Device for Aerosol Oxidative Activity,” Sameenoi, Y.; Panymeesamer, P.; Supalakorn, N.; Koehler, K.; Chailapakul, O.; Henry, C.; Volckens, J., Environ. Sci. Technol.201347, 932-940.

74. “Spatially resolved electrochemical sensing of chemical gradients,” Mensack, M.; Wydallis, J.; Lynn, N.; Dandy, D.; Henry, C., Lab Chip201313, 208-211.

 

2012

73. “Electrophoretic separations in poly(dimethylsiloxane) microchips using mixtures of ionic, nonionic and zwitterionic surfactants,” Guan, Q.; Noblitt, S. D.; Henry, C. S., Electrophoresis2012, 33, 2875-2883.

72. “Microfluidic Electrochemical Sensor for On-Line Monitoring of Aerosol Oxidative Activity,” Sameenoi, Y.; Koehler, K.; Shapiro, J.; Boonsong, K.; Sun, Y.; Collett, Jr., J.; Volckens, J.; Henry, C. S., J. Am. Chem. Soc.2012134, 10562-10568.

71. “Blood Separation on Microfluidic Paper-Based Analytical Devices,” Songjaroen, T.; Dungchai, W.; Chailapakul, O.; Henry, C. S.; Laiwattanapaisal, W., Lab Chip2012, 18, 3392-3398.

70. “Simple Silver Nanoparticle Colorimetric Sensing for Copper by Paper-Based Devices,” Ratnarathorn, N.; Chailapakul, O.; Henry, C. S.; Dungchai, W., Talanta2012, 99, 552-557.

69. “Sodium Dodecyl Sulfate Modified Electrochemical Paper-Based Analytical Device for Determination of Dopamine Levels in Biological Samples,” Rattanarat, P.; Dungchai, W.; Siangprob, W.; Chailapakul, O.; Henry, C. S., Anal. Chim. Acta2012, 744, 1-7.

68. “Microfluidic Paper-Based Analytical Device for Particulate Metals,” Mentele, M. M.; Cunningham, J. C; Koehler, K.; Volckens, J.; Henry, C. S., Anal. Chem.2012, 84, 4474-4480.

67. “Development of a Paper-Based Analytical Device for Colorimetric Detection of Select Foodborne Pathogens,” Jokerst, J. C.; Adkins, J. A.; Bisha, B.; Mentele, M. M.; Goodridge, L. D.; Henry, C. S., Anal. Chem.201284, 2900-2907.

66. “Mapping Spatiotemporal Molecular Distributions Using a Microfluidic Array,” Lynn, N. S.; Tobet, S.; Henry, C. S.; Dandy, D. S., Anal. Chem., 2012, 84, 1360-1366.

65. “Advances in Microfluidics for Environmental Analysis,” Gertsch, J.; Emory, J.; Henry, C. S., Analyst, 2012, 137, 24-34.

64. “Competitive, Non-Competitive, and Mixed Format Cleavable Tag Immunoassays,” Sameenoi, Y.; Mensack, M. M.; Murphy, B. M.; Henry, C. S., Methods, 2012, 56, 166-173.

63. “Electrophoretic separations in poly(dimethylsiloxane) microchips using a mixture of ionic and zwitterionic surfactants,” Guan, Q.; Noblitt, S. D.; Henry, C. S., Electrophoresis, 2012, 33, 379-387.

 

2011

62. “Characterization of Novel Microelectrode Geometries for Detection of Neurotransmitters,” Pettine, W.; Jibson, M.; Chen, T.; Tobet, S.; Nikkel, P.; Henry, C. S., IEEE Sensors, 2011, 12, 1187-1192.

61. “Protonated diamines as anion binding agents and their utility in capillary electrophoresis separations,” Noblitt, S. D.; Speights, R. M.; Henry, C. S., Electrophoresis, 2011, 32, 2986-2993.

60. “Poly(dimethysiloxane) Cross-linked Carbon Paste Electrodes for Microfluidic Electrochemical Sensing,” Sameenoi, Y.; Mensack, M. M.; Boonsong, K.; Ewing, R.; Dungchai, W.; Chailapakul, O.; Cropek, D. M.; Henry, C. S., Analyst, 2011136, 3177-3184.

59. “Culturing and Investigation of Stress-Induced Lipid Accumulation in Microalgae Using a Microfluidic Device,” Holcomb, R. E.; Mason, L. J.; Reardon, K. F.; Cropek, D. M.; Henry, C. S., Anal. Bioanal. Chem., 2011, 400, 245-53.

 

2010

58. “A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing,” Dungchai, W.; Chailapakul, O.; Henry, C.S., Analyst, 2010, 136, 77-82.

57. “Use of multiple colorimetric indicators for paper-based microfluidic devices,” Dungchai, W.; Chailapakul, O.; Henry, C.S., Anal. Chim. Acta, 2010, 674, 227-233.

56. “Rapid Analysis of Perchlorate in Drinking Water at Parts per Billion Levels Using Microchip Electrophoresis,” Gertsch, J.; Noblitt, S. D.; Cropek, D. M.; Henry, C. S Anal. Chem., 2010, 82, 3426-3429.

55. “Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron,” Apilux, A.; Dungchai, W.; Siangproh, W.; Praphairaksit, N.; Henry, C. S., Chailapakul, O., Anal. Chem., 2010, 82, 1727-1732.

 

2009

54. “Interfacing microchip electrophoresis to a growth tube particle collector for semi-continuous monitoring of aerosol composition,” Noblitt, S. D.; Lewis, G. S.; Liu, Y.; Hering, S. V.; Collett, Jr, J. L.; Henry, C. S., Anal. Chem., 2009, 81, 10029-10037.

53. “Improving MCE with electrochemical detection using a bubble cell and sample stacking techniques,” Guan, Q.; Henry, C. S., Electrophoresis, 2009, 30, 3339-3346.

52. “Review: Microfluidic Applications in Metabolomics and Metabolic Profiling,” Kraly, J. R.; Holcomb, R. E.; Guan, Q.; Henry, C. S., Anal. Chim. Acta, 2009, 653, 23-35.

51. “Electrochemical Detection for Paper-Based Microfluidics,” Dungchai, W.; Chailapakul, O.; Henry, C. S., Anal. Chem., 2009, 81, 5821-5826.

50. “Photopatternable carbon electrodes for chip-based electrochemical detection,” Gonzalez, C. D.; Cropek, D. M.; Henry, C. S., Electroanalysis, 2009, 21, 2171-2174.

49. “Evaporation from Microreservoirs,” Lynn, N. S.; Henry, C. S.; Dandy, D. S., Lab Chip, 2009, 9, 1780-1788.

48. “Analysis of Oxidative Stress Biomarkers Using a Simultaneous Competitive/Non-Competitive Micromosaic Immunoassay,” Murphy, B. M.; Dandy, D. S.; Henry, C. S., Anal. Chim. Acta, 2009, 640, 1-9.

47. “High-sensitivity microchip electrophoresis determination of inorganic anions and oxalate in atmospheric aerosols with adjustable selectivity and conductivity detection,” Noblitt, S. D.; Henry, C. S., J. Chromatogr. A, 2009, 1216, 1503-1510.

46. “Electrode Array Detector for Microchip Capillary Electrophoresis,” Holcomb, R.; Kraly, J.; Henry, C. S., Analyst, 2009, 134, 486-492.

 

2008

45. “Evanescent field response to immunoassay layer thickness on planar waveguides,” Yan, R.; Yuan, G.; Stephens, M. D.; He, X.; Henry, C. S.; Dandy, D.S.; Lear, K. L., Appl. Phys. Lett., 2008, 93, 101110.

44. “Improving the Compatibility of Contact Conductivity Detection with Microchip Electrophoresis Using a Bubble Cell,” Noblitt, S. D.; Henry, C. S., Anal. Chem., 2008, 80, 7624-7630.

43. “Measuring Reaction Rates on Single Particles in a Microfluidic Device,” Caulum, M. M.; Henry, C. S., Lab Chip, 2008, 8, 865-867.

42. “Influence of Polymer Structure on Electroosmotic Flow and Separation Efficiency in Successive Multiple Ionic Layer Coatings for Microchip Electrophoresis,” Boonsong, K.; Caulum, M. M.; Dressen, B. M.; Chailapakul, O.; Cropek, D. M.; Henry, C. S., Electrophoresis, 2008, 29, 3128-3134.

41. “Chaotic advection produced via transverse electrokinetic effects in a planar microchannel,” Lynn, N. S.; Dandy, D. S.; Henry, C. S., Microfluid. Nanofluid., 2008, 5, 493-505.

40. “Competitive Immunoassay Methods for Simultaneous Detection of Metabolites and Proteins Using Micromosaic Patterning,” Murphy, B. M.; He, X.; Dandy, D. S.; Henry, C. S., Anal. Chem., 2008, 80, 444-450.

39. “Microfluidic Protein Patterning on Silicon Nitride Using Solvent Extracted Polydimethylsiloxane Channels,” He, X., Dandy, D. S.; Henry, C. S., Sens. Actuat. B, 2008, 129, 811-817.

 

2007

38. “Integrated Membrane Filters for Minimizing Hydrodynamic Flow and Filtering in Microfluidic Devices,” Noblitt, S. D.; Kraly, J. R.; VanBuren, J. M.; Hering, S. V.; Collett Jr., J. L.; Henry, C. S., Anal. Chem., 2007, 79, 6249-6254.

37. “Detection of Cardiac Biomarkers Using Micellar Electrokinetic Chromatography and a Cleavable Tag Immunoassay,” Caulum, M. M.; Murphy, B. M.; Ramsey, L. M.; Henry, C. S., Anal. Chem., 2007, 79, 5249-5256.

36. “Plasma Modification of PDMS Microfluidic Devices for Control of Electroosmotic Flow,” Martin, I. T.; Dressen, B. M.; Boggs, M.; Liu, Y.; Henry, C. S.; Fisher, E. R., Plasma Proc. Polym., 2007, 4, 414-424, cover article.

35. “Separation of common organic and inorganic anions in atmospheric aerosols using a piperazine buffer and capillary electrophoresis,” Noblitt, S. D.; Mazzoleni, L. R.; Collett, J. L.; Hering, S. V.; Henry, C. S., J. Chromatogr. A, 2007, 1154, 400-406.

34. “Thermoset polyester as an alternative material for microchip electrophoresis/electrochemistry,” Vickers, J. J.; Dressen, B. M.; Boonsong, K.; Cropek, D.; Henry, C. S., Electrophoresis, 2007, 28, 1123-1129.

 

2006

33. “Multi-Analyte Immunoassay using Cleavable Tags and Microchip Micellar Electrokinetic Chromatography,” Caulum, M. M.; Henry, C. S., Analyst, 2006, 131, 1091-1093.

32. “Generation of Hydrophilic Poly(dimethylsiloxane) for High Performance Microchip Electrophoresis,” Vickers, J. A.; Caulum, M. M.; Henry, C. S., Anal. Chem. 2006, 78, 7446-7452.

31.  “Analysis of anions in ambient aerosols by microchip capillary electrophoresis,” Liu, Y.; MacDonald, D. A.; Yu, X. Y.; Hering, S. V.; Collett, J. L.; Henry, C. S., Analyst, 2006, 131, (11), 1226-1231.

30. “Second virial coefficient determination of a therapeutic peptide by self-interaction chromatography,” Payne, R. W.; Nayar, R.; Tarantino, R.; Del Terzo, S.; Moschera, J.; Di, J.; Heilman, D.; Bray, B.; Manning, M. C.; Henry, C. S., Biopolymers, 2006, 84, (5), 527-33.

29. “Screening for physical stability of a Pseudomonas amylase using self-interaction chromatography,” Valente, J. J.; Fryksdale, B. G.; Dale, D. A.; Gaertner, A. L.; Henry, C. S., Anal. Biochem., 2006, 357, (1), 35-42.

28. “Effect of Buffer Species on the Thermally Induced Aggregation of Interferon-tau,” Katayama, D. S.; Nayar, R.; Chou, D. K.; Valente, J. J.; Cooper, J.; Henry, C. S.; Vander Velde, D. G.; Villarete, L.; Liu, C. P.; Manning, M. C., J. Pharm. Sci.,2006, 95, (6), 1212-1226.

 

2005

27. “Second virial coefficient studies of cosolvent-induced protein self-interaction,” Valente, J. J.; Verma, K. S.; Manning, M. C.; Wilson, W. W.; Henry, C. S., Biophys. J., 2005, 89, (6), 4211-8.

26. “Simplified current decoupler for microchip capillary electrophoresis with electrochemical and pulsed amperometric detection,” Vickers, J. A.; Henry, C. S., Electrophoresis, 2005, 26, (24), 4641-4647.

25. “Coupling Capillary Electrophoresis with Pulsed Electrochemical Detection,” Garcia, C. D.; Henry, C. S., Electroanalysis, 2005, 17, 1125-1131.

24. “Comparison of surfactants for dynamic surface modification of poly(dimethylsiloxane) microchips,” Garcia, C. D.; Dressen, B. M.; Henderson, A.; Henry, C. S., Electrophoresis, 2005, 26, 703-709.

23. “Comparison of pulsed electrochemical detection modes coupled with microchip capillary electrophoresis,” Garcia, C. D.; Henry, C. S., Electroanalysis, 2005, 17, 223-230.

22. “Analysis of natural flavonoids by microchip-micellar electrokinetic chromatography with pulsed amperometric detection,” Hompesch, R. W.; Garcia, C. D.; Weiss, D. J.; Vivanco, J. M.; Henry, C. S., Analyst, 2005, 130, 694-700.

21. “Determination of levoglucosan from smoke samples using microchip capillary electrophoresis with pulsed amperometric detection,” Garcia, C. D.; Engling, G.; Herckes, P.; Collett, J. L. Jr.; Henry, C. S., Environ. Sci. Technol., 2005, 39, 618-623.

 

2004

20. “Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection,” Garcia, C. D.; Henry, C. S., Anal. Chim. Acta, 2004, 508, 1-9.

19. “Direct detection of renal function markers using microchip CE with pulsed electrochemical detection,” Garcia, C. D.; Henry, C. S., Analyst, 2004, 129, 579-584.

18. “Simple and sensitive electrode design for microchip electrophoresis/electrochemistry,” Liu, Y.; Vickers, J. A.; Henry, C. S., Anal. Chem., 2004, 76, 1513-1517.

17. “Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis,” Garcia, C. D.; Liu, Y.; Anderson, P.; Henry, C. S., Lab Chip, 2004, 3, 324-328.

 

2003

16. “Recent progress in the development of mu TAS for clinical analysis,” Liu, Y.; Garcia, C. D.; Henry, C. S., Analyst, 2003, 128, 1002-1008.

15. “Direct determination of carbohydrates, amino acids, and antibiotics by microchip electrophoresis with pulsed amperometric detection,” Garcia, C. D.; Henry, C. S., Anal. Chem., 2003, 75, 4778-4783.

14. “Experimental Studies of Electroosmotic Flow Dynamics in Microfabricated Devices during Current Monitoring Experiments,” Pittman, J. L.; Henry, C. S.; Gilman, S. D., Anal. Chem., 2003, 75, 361-370.

13. “Screening of protein-ligand interactions by affinity chromatography,” Garcia, C. D.; Holman, S. C.; Henry, C. S.; Wilson, W. W., Biotech. Prog., 2003, 19, 575-579.

12. “Measuring Protein Interactions by Microchip Self-Interaction Chromatography,” Garcia, C. D.; Hadley, D. J.; Wilson, W. W.; Henry, C. S., Biotech. Prog., 2003, 19, 1006-1010.

 

2002

11. “Pulsed amperometric detection of carbohydrates on an electrophoretic microchip,” Fanguy, J. C.; Henry, C. S., Analyst, 2002, 127, 1021-1023.

10. “The analysis of uric acid in urine using microchip capillary electrophoresis with electrochemical detection,” Fanguy, J. C.; Henry, C. S., Electrophoresis, 2002, 23, 767-773.

 

2001

9. “Conductivity detection for monitoring mixing reactions in microfluidic devices,” Liu, Y.; Wipf, D. O.; Henry, C. S., Analyst, 2001, 126, 1248-1251.

8. “High-throughput multi-analyte screening for renal disease using capillary electrophoresis,” Clark, E. A.; Fanguy, J. C.; Henry, C. S., J. Pharm. Biomed. Anal., 2001, 25, 795-801.

 

2000

7. “Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips,” Liu, Y.; Fanguy, J. C.; Bledsoe, J. M.; Henry, C. S., Anal. Chem., 2000, 72, 5939-5944.

6. “Dual-Electrode Electrochemical Detection for Poly(dimethylsiloxane)-Fabricated Capillary Electrophoresis Microchips,” Martin, R. S.; Gawron, A. J.; Lunte, S. M.; Henry, C. S., Anal. Chem., 2000, 72, 3196-3202.

 

1999

5. “Microcavities and micropores for electrochemical analysis,” Holsten, N. D.; Bowen, B. P.; Vandaveer, W. R. I. V.; Henry, C. S.; Fritsch, I.; Lenihan, T. G., Proc. Electrochem. Soc., 1999, 99, 67-81.

4. “Microfabricated Recessed Microdisk Electrodes: Characterization in Static and Convective Solutions,” Henry, C. S.; Fritsch, I., Anal. Chem., 1999, 71, 550-556.

3. “Ceramic microchips for capillary electrophoresis-electrochemistry,” Henry C. S.; Zhong, M;, Lunte, S. M.; Kim, M.; Bau, H.; Santiago, J. J., Anal. Comm., 1999, 36, 305-307.

2. “Microcavities containing individually addressable recessed microdisk and tubular nanoband electrodes,” Henry, C. S.; Fritsch, I., J. Electrochem. Soc., 1999, 146, 3367-3373.

 

1998

1. “Formation and Characterization of Supported Hexadecanethiol/Dimyristoyl Phosphatidylcholine Hybrid Bilayers Containing Gramicidin D,” Henry, C. S.; Fritsch, I., Langmuir, 1998, 14, 5850-5857.